application: Servo and main spindle motors
location of B-side power connector: Top
optional blower unit location: Attached to motor
blower unit operation voltage: AC 115 – 230 V
operation voltage tolerance: ± 10/15 %
Operation frequency: 50/60 Hz
blower unit application: Surface cooling during high load applications
continuous torque at standstill (60-K/100-K overtemperature): 57 Nm
continuous current at standstill (60-K/100-K overtemperature): 39.9 A
normal operation continuous current (60-K/100-K overtemperature): 26.6/32.6 A
Normal operation continuous torque at standstill (60-K/100-K overtemperature): 38/43.5 Nm
pole pairs: 4
winding inductance: 6.7 mH
installation: B05 flange mounting
maximum installation height: 1000 meters above sea level
housing paint: Prime black coat
holding brake: Installed
shaft: Keyed, protected by a radial shaft sealing ring
protection standard: IP 65