Rated Current Output: 200 Amps
Function ID: 04
Function ID Version: 00
Nominal Voltage: 300 Volts DC
Voltage Tolerance: 15%
Input Voltage Rating: 24 Volts DC
Power Supply Requirement: Regulated DC output
DC Power Supply Capability: Multiple DDS Drives
Ambient Temperature Range: 0 to 45 degrees Celsius
Recommended Spacing (Front): 40 millimeters
Recommended Spacing (Top and Bottom): 80 millimeters
Feedback Methods Supported: Digital Servo Feedback and Resolver Feedback
Command Communication Module: SERCOS
Data Transfer Rates: 2 / 4 Mbps
Network Topology: Ring
Data Transmission Medium: Fiber Optic Cable
Installation Requirement: Trained personnel only