Function ID Code: 09
Ready-to-operate Contact: Bb
Continuous and Short-term Switching Capacity: 24VDC/1A
Analog Diagnostic Outputs: 2
Connection Type: DC Bus Rails
Control Electronics Connector: X1
Interface Type: RS 232
Motor Power Cable: Three-phase
Motor Power Connection Lines: 3
Protective Conductor Connection Line: 1
Mounting Type: Back Wall of a Control Cabinet
L+, L- and PE terminals: M5 screws with a tightening torque of 3Nm
Required Clearance: 80mm top and bottom of the control cabinet
Degree of Protection: IP 10 per DIN 40 050 specifications
Protection Against Solid Objects: More than 50mm in Diamete